For the calculation you will need:
— Chamber volume (V, m³).
— Pump speed (S, m³/h).
— Initial pressure (P₁, mmHg) and final pressure (P₂, mmHg).
— Pump-down curve factor (F) – depends on P₂.
To avoid manual calculations, we have created a convenient calculator – simply enter the parameters and get the approximate pump-down time.
The factor (F) depends on the final pressure (P₂):
| P₂ Range (mmHg) | Factor F |
|---|---|
| 750–187 | 1 |
| 187–75 | 1.5 |
| 75–37 | 1.75 |
| 37–15 | 2 |
| 15–3 | 2.5 |
| 3–0.7 | 3 |
The calculator will be useful for:
— Engineers and technologists – to select vacuum equipment faster.
— Service specialists – to check the efficiency of vacuum systems.
— Beginners – to avoid mistakes in settings.
We use this calculator ourselves – it helps us select pumps and configure pump-down modes for vacuum furnaces.
On the page you will find additional necessary information:
— Comparative pump tables – to choose a model for your tasks. Some of them are available in our catalog – you can view specifications and purchase immediately.
— Volumes of standard vacuum furnaces in different units – estimate the pump-down time for your equipment. For selection, you can use our recommendations.
⚠ Important!
— The calculation is valid for dry air at standard humidity. If the chamber contains moisture or impurities, the time may differ.
— If moisture is present in the volume, please refer to additional recommendations.
Need help selecting equipment? Ask us – we will find the optimal solution! → Go to catalog.